ID 46016
FB error: There is no axis with this name in axis group. | |||
Description | A function block that displays this error message contains axis-specific information that is part of the job for an axis group, and this information is transmitted to the motion controller. The motion controller detects that there is no axis with this name in the assigned axis group. This name is stored as a string in a structure of type IDENT_IN_GROUP_REF in the variable "Name". This structure is transferred to the function block at the "IdentInGroup" input. | ||
Response | Class | - | The job results in no response from the motion controller. |
Solution | Class | - | Correct the string stored in the "Name" variable. Afterwards, the character string must correspond to a name of an axis in the commanded axis group. |
Error type | - | ||
| |||