ID 44025
FB error: order not allowed, because aborting touch probing is still active. | |||
Description | This is an error of an instance of the MC_TouchProbe or MC_AbortTrigger. The commanded FB also sets the “Error” output to TRUE in the same PLC cycle and displays this error message at the “ErrorID” output because a touch probing order is still active and not acknowledged until now. | ||
Response | Class | - | The job is dismissed by the FB and not issued to the motion controller. |
Solution | Class | - | If the error code is displayed, wait until the previous commanded probing abort is acknowledged before placing a new job. In general, a probing process must be prevented from starting or the abort of a probing process must be prevented as long as an order to abort a probing process is still active. |
Error type | - | ||
| |||