ID 44018
FB error: order not allowed, because axis is in state DISCRETE_MOTION. | |||
Description | An order should be send via an FB to the motion controller. The commanded FB also sets the “Error” output to TRUE in the same PLC cycle and displays this error message at the “ErrorID” output because a motion command, triggered by an instance of an FB MC_MoveAbsolute, MC_MoveAdditive, MC_MoveRelative or MC_MoveSuperImposed is still active for this axis. This order had not yet been acknowledged with “Done” = TRUE. | ||
Response | Class | - | The order is dismissed by the FB and not issued to the motion controller. |
Solution | Class | - | General there exist three possibilities to handle the situation:
Afterwards, it’s possible to reassign the FB that notified the error code. |
Error type | - | ||
| |||