Copying of version string from HLI into PLC's string variable failed. | |||
Description | A PLC application that uses PLC libraries containing function blocks according to the PLCopen specifications to solve function blocks must call exactly one instance of the MCV_PlatformBase function block. During the initialisation phase of the Motion Control Platform, the utility FB MCV_ChkHLIVer is called within the FB MCV_PlatformBase to check whether the version identifiers of the HLI interface of the PLC and motion controller match. The utility FB displays this error message if the version identifier of the motion controller cannot be copied to the PLC. At the output "ErrorID" of the FB MCV_PlatformBase this error message is made available for the PLC application. | ||
Response | Class | - | The FB MCV_PlatformBase sets sets its “Error” output to TRUE and the “Done” output to FALSE. |
Solution | Class | - | Please contact the controller supplier and quote the error number. |
Error type | - | ||
| |||