ID 40002
Axes group specific MC error. | |||
Description | Due to an error in the Motion Controller, the axis group is in the state GroupErrorStop, according to the state diagram defined in the PLCopen specification for axis groups [MCP-P4//Chapter: PLCopen axis group state model]. The FB whose job resulted in the error in the Motion Controller and applied this axis group as a reference to its “AxesGroup” input displays this error code at its “ErrorID” output pin and sets the “Error” output to TRUE. | ||
Response | Class | - | The reaction of the motion controller depends on the concrete occurred error. |
Solution | Class | - | To diagnose which specific axis group error has occurred in the Motion Controller, the output "GroupErrorID" of an FB of type MC_GrpReadError must be evaluated, which has this axis group assigned at the input "AxesGroup" as axis group reference. The error can be reset by executing an instance of the MC_GrpReset for this group of axes. |
Error type | - | ||
| |||