ID 21850
Missing axis may not be part of rotation or translation. | ||||
Description | The channel parameter P-CHAN-00213 can also be used for Cartesian transformations #CS (see [PROG//Definition of a machining coordinate system]) if not all main axes are present (i.e. the first three axes of an NC channel). However, the following limitations exist: Programming a translatory shift for a missing axis is not allowed The rotation must be in the plane of the two available axes meaning only a rotation around the missing axis is permitted. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Correct the NC program or exchange the main axes in the CNC channel (see [PROG//Requesting of axes]) | |
Parameter | %1: | Error value [-] | ||
Index of the missing axis (in the active working plane) | ||||
Error type | 1, Error message from NC program. | |||
| ||||