ID 21578
Double programming of H-function by tube profile parameter. | ||||
Description | The parameter setting of active function tube profile machining #CYL[] contains double setting of M/H number. Assignment in section h_synch[<H-Number>] or m_synch[<M-Number>] and tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off. Invalid parameter setting leads to deactivation of specific M/H-Code output for #CYL[] function. | |||
Response | Class | 1 | Start-up of the control is continued. | |
Solution | Class | 1 | Check and correct parameter settings of channel machine data in tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off. | |
Parameter | %1: | Error value [-] | ||
Current M/H number with double setting from h_synch[] or m_synch[] | ||||
%2: | Corrected value [-] | |||
Assigned M/H value off tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off | ||||
%3: |
| |||
Corrected value off tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||