ID 21404
Channel parameters: Multiple axes programming without active "multi_dimension_in_block" is not useful. | ||||||
Description | During start-up, the channel parameter check determines that it only makes sense to set P-CHAN-00148 to 1 if P-CHAN-00116 is also set to 1. | |||||
Response | Class | 1 | Start-up of the control is continued. | |||
Solution | Class | 1 | During start-up in case of conflict the multiple axes programming is set to 0 (FALSE) and the start-up is continued. Before the next start-up, set the channel parameters P-CHAN-00116 and P-CHAN-00148 correctly: | |||
P-CHAN-00116 | P-CHAN-00148 | Check result | ||||
0 | 0 | OK | ||||
1 | 0 | OK | ||||
1 | 1 | OK | ||||
0 | 1 | NOT OK | ||||
Parameter | %1: | Error value [-] | ||||
Channel parameter P-CHAN-00148 incorrectly assigned | ||||||
%2: | Corrected value [-] | |||||
| ||||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||||
| ||||||