ID 21397
Coordinate system transition during active OTC not allowed. | |||
Description | During the transition of coordinate systems with the commands #CS, #ACS and/or #MCS, the OTC function (Online Tool Compensation) may not be enabled. This restriction applies both to the selection and deselection of the respective function. Example: Wrong: N10 G00 X0 Y0 Z0 N20 #OTC ON [LENGTH CONT WEAR_CONST_TOOL] N30 #CS ON [10,20,30,0,0,45] : N900 #OTC OFF N1000 M30 Correct: N10 G00 X0 Y0 Z0 N20 #CS ON [10,20,30,0,0,45] N30 #OTC ON [LENGTH CONT WEAR_CONST_TOOL] : N900 #OTC OFF N1000 M30 | ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and modify NC program. Select the ORC function only after the coordinate system transition (#OTC ON [...]). |
Error type | 1, Error message from NC program. | ||
| |||