ID 21384
Impermissible use of a cycle centre point coordinate. | ||||
Description | This error output is caused when using a cycle center point coordinate (@I..) in the main program, or by a direct call of a cycle as a stand-alone program. A cycle centre point coordinate may only be used in the cycle program itself (e.g. @I= @P6)
Example with error: N05 X0 Y0 Z0 G00
N20 G01 @I=100 X200 F500
N40 L CYCLE [NAME=dummy1.cyc …]
N50 G01 Y300 F1000
N60 G01 Z300 F2000
N90 M30
| |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. . Use cycle centre point coordinates only in the cycle. Start cycle only by a global sub program call within the main program (L CYCLE [...]). | |
Parameter | %1: | Current value [-] | ||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||