ID 21363
Axis to define control range not permissible. | ||||
Description | Only the first 2 main axes, that form the working plane (G17, G18, G19) may be programmed for the definition of the contour of a control area. The third main axis and all other coupled axes shall not be programmed during the definition of a control area contour. Example: Wrong:
N10 #CONTROL AREA START [ID1 WORK POLY …]
N20 G01 F1000 G90 X-150 Y75 (Starting point)
N30 X-50 Y150 Z200
:
N130 X-150 Y75
N140 #CONTROL AREA END
:
N1000 M30
Correct:
N10 #CONTROL AREA START [ID1 WORK POLY …]
N20 G01 F1000 G90 X-150 Y75 (Starting point)
N30 X-50 Y150 Z200
:
N130 X-150 Y75
N140 #CONTROL AREA END
:
N1000 M30
| |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. Ensure, that only the first 2 main axes are used for the definition of the contour of a control area. See also [PROG// Chapter - Definition of a control area] | |
Parameter | %1: | Logical axis number | ||
Logical axis number of impermissible programmed axis | ||||
Error type | 1, Error message from NC program. | |||
|