ID 21287
Definition of a previous control area has not been finished. | |||
Description | It is noted that the definition of a new control area with #CONTROL AREA BEGIN[...] is still programmed within the NC program sequence of the previous control area. But the nested definition of control areas is not allowed. Syntax example: :
N10 #CONTROL AREA BEGIN...
N20 G01 X10 Y10
N30 G01 X20 Y20
N40 #CONTROL AREA BEGIN... -> ERROR
:
Nxx #CONTROL AREA END
:
| ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and modify NC program. The definition of a new control area only is permissible, if the definition of a previous control area is finished with #CONTROL AREA END. Syntax example: :
N10 #CONTROL AREA BEGIN...
N20 G01 X10 Y10
N30 G01 X20 Y20
:
Nxx #CONTROL AREA END
Nxx #CONTROL AREA BEGIN...
|
Error type | 1, Error message from NC program. | ||
| |||