ID 21280
With #SAVE CONFIG, too many coupling pairs are to be saved. | ||||
Description | When using the #SAVE CONFIG[AXLINK] command, the total number of coupled axis pairs of all enabled axis coupling groups to be saved is too large. The total number of coupling pairs to be backed up is limited because #LOAD CONFIG[AXLINK] implicitly assigns coupling group 1 to the restore, which can also only hold a limited number of coupling pairs. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. Before using #SAVE CONFIG, if possible reduce the number of active axis coupling groups with #DISABLE AX LINK or #AX LINK OFF. | |
Parameter | %1: | Error value [-] | ||
| ||||
%2: | Limit value [-] | |||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||