ID 21142
Contour rotation not possible, if 1st or 2nd main axis is not available. | ||||
Description | When contour rotation (#ROTATION) was selected, the system detects that the first or second main axis is missing in the NC channel. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify the axis configuration of the NC channel. The error cause may be e.g. an incomplete basic configuration in the channel parameter list or the first or second main axis from the channel was released when axis exchange commands are used in the NC program. | |
Parameter | %1: | Incorrect value [-] | ||
String acts as reference for which main axis is missing. FIRST: first main axis SECOND: second main axis | ||||
Error type | 1, Error message from NC program. | |||
| ||||