ID 20857
Channel parameters: Enabling of external tool management not permitted, because no external tool management is available. | ||||
Description | Since the current system configuration basically does not allow external tool management, but the tool data is loaded exclusively via the tool list [TOOL], it does not make any sense to assign P-CHAN-00016 with 1. | |||
Response | Class | 1 | Controller start-up is continued. | |
Solution | Class | 1 | Parameter is set implicitly to default value 0. Or please contact the CNC manufacturer to enable the use of an external tool management. | |
Parameter | %1: | Error value [-] | ||
Channel parameter P-CHAN-00016 incorrectly assigned | ||||
%2: | Corrected value [-] | |||
| ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||