ID 20766

Double-programmed H-function.

Description

In the NC block, an H function (techno function) with the same number is programmed several times channel-specifically, axis-specifically or spindle-specifically.

 

Example for inadmissible double programming:

N10 G00 X10 H10 H10 (channel-specific technofct.)
N10 G00 X10 X[H10] X[H10]] (axis-specific technofct.)
N10 G00 X10 S[H10 H10] (spindle-specific technofct.)
:

Example for allowed programming:

N10 G00 X10 H10 X[H10] S[H10] (combined technofct.)

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify the programming of the H functions in the NC block. Remove surplus channel specific, axis specific or spindle specific H functions.

Parameter

%1:

Current value [-]

Number of the multiple programmed H function

Error type

1, Error message from NC program.