ID 20718
| Unknown receiver ID during #MSG... | ||||
| Description | The receiver ID programmed with #MSG is not known in the NC channel or in the system. This is why the message is not output. | |||
| Response | Class | 2 | Abort NC program processing. | |
| Solution | Class | 3 | Check and modify NC program. Specify a permissible receiver ID with #MSG. See also [PROG//Section: Programming a message] | |
| Parameter | %1: | Error value [-] | ||
| Programmed value of receiver ID | ||||
| %2: | Expected value [-] | |||
| Permissible value of receiver ID of CNC diagnosis interface. | ||||
| %3: | Expected value[-] | |||
| Permissible value of receiver ID of PLC | ||||
| %4: | Expected value[-] | |||
| Permissible value of receiver ID of HMI | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||