ID 20707
| Program paths of the same type are not allowed to have the same priority. | ||||
| Description | The start-up list contains configured program paths that may be of the same type as P-STUP-00020 but may not have the same priority asP-STUP-00021. 
 Example with error: pfad[0].prg[0]          v:\ref_test\nc_prg\init pfad[0].log_nr[0]       1 pfad[0].typ[0]          0x03 pfad[0].prioritaet[0]   1 # pfad[0].prg[1]          v:\ref_test\nc_prg\dec pfad[0].log_nr[1]       1 pfad[0].typ[1]          0x03 pfad[0].prioritaet[1]   1 | |||
| Response | Class | 2 | Controller start-up is aborted. | |
| Solution | Class | 6 | Check and modify the priority settings for program paths in the start-up list. Repeat the NC start-up. | |
| Parameter | %1: | Error value [-] | ||
| Invalid priority P-STUP-00021 | ||||
| %2: | Current value [-] | |||
| Program path type P-STUP-00020 | ||||
| Error type | - | |||
| 
 | ||||