ID 20662
TOOL ORI CS needs a rotary axis. | ||||
Description | With the NC command #TOOL ORI CS (tool orientation perpendicular to the rotated machining plane), the system detects that a rotary axis necessary for the tool orientation is not available in NC channel. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check the order of the main axes and rotary axes in the NC channel and adjust them according to the basic kinematic. As a rule at least two rotary axes are necessary for automatic tool orientation. For further information see [PROG//Section – Orienting tool] Ensure that no axes required for alignment were sent out of the channel by axis exchange commands or are incorrectly arranged in the axis order (e.g. gaps). | |
Parameter | %1: | Current value [-] | ||
Place or index in axis order where a rotary axis is expected. | ||||
Error type | 1, Error message from NC program. | |||
| ||||