ID 20658
Not enough axes for RTCP/TLC. | ||||
Description | Depending on the specific machine kinematic in NC channel, a minimum number of axes is necessary at selection of kinematic transformation (#TRAFO ON). This axes have to be in a fixed order without any gap. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and adjust the order of the channel axes. Make sure that no wrong kinematic ID (#KIN ID[...]) has been selected, and that no axes required for the kinematic transformation have been removed from the channel by axis exchange commands. | |
Parameter | %1: | Error value [-] | ||
Number of axes in NC channel up to the first gap | ||||
%2: | Current value [-] | |||
Number of necessary axes for the enabled machine kinematics without a gap | ||||
Error type | 1, Error message from NC program. | |||
| ||||