ID 20571
PDU received from tool management contains invalid parameter index. | ||||
Description | An external tool management provides the corresponding tool data in segmented data packages (PDUs) based on the request from the NC program (D word, #TOOL DATA). On this occasion the plausibility check of the received data in the NC channel detects, that the segmentation index of the tool parameters is not correct. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 6 | Check and modify processing and supply of requested data in external tool management. | |
Parameter | %1: | Error value [-] | ||
Inadmissible parameter index | ||||
%2: | Lower limit value [-] | |||
| ||||
%3: | Upper limit value [-] | |||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||