ID 20472
Coupling description may not be changed. | ||||
Description | When defining a coupling group, the system detects that this coupling group is still currently active. Example: Wrong: N10 G00 X0 Y0 Z0 N20 #SET AX LINK[1,C=X] N30 #ENABLE AX LINK[1] : N100 #SET AX LINK[1,C=Y] : N1000 M30 Correct: N10 G00 X0 Y0 Z0 N20 #SET AX LINK[1,C=X] N30 #ENABLE AX LINK[1] : N90 #DISABLE AX LINK[1] N100 #SET AX LINK[1,C=Y] : N1000 M30 For further information see [PROG// Section: Programming axis couplings] | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. The active access group must first be deactivated before a new definition can be made. | |
Parameter | %1: | Error value [-] | ||
Number of the coupling group | ||||
Error type | 1, Error message from NC program. | |||
| ||||