ID 20457
De-/selection of synchronous operation not allowed during active TRC. | |||
Description | During active tool radius compensation (TRC, G41/G42), the selection/ deselection of synchronous operation mode of axes is not permissible. Example: Wrong:
N10 #SET AX LINK [ 1, C=X ]
N20 G41
N30 #ENABLE AX LINK [1]
N30 X100
N40 G40
N50 #DISABLE AX LINK [1]
N60 X0
Correct:
N10 #SET AX LINK [ 1, C=X ]
N30 #ENABLE AX LINK [1]
N20 G41
N30 X100
N40 G40
N50 #DISABLE AX LINK [1]
N60 X0
| ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and adjust NC program sequence. Activate synchronous operation before selecting the radius compensation (G41/G42) or deactivate tool radius compensation before deselecting synchronous operation (G40). |
Error type | 1, Error message from NC program. | ||
| |||