ID 20426
Channel parameters: Axis is configured both as spindle and as path axis. | ||||
Description | During start-up, the check of the channel parameter detects that a path axis and a spindle axis have the same logical axis number P-CHAN-00035 (P-CHAN-00035, P-CHAN-00036). | |||
Response | Class | 1 | Start-up of the control is continued. | |
Solution | Class | 1 | Check and change the logical axis numbers of the path axes P-CHAN-00035 and spindle axes P-CHAN-00036 in the channel parameter list. In the system, a logical axis number only may be assigned to one single axis. | |
Parameter | %1: | Logical axis number [-] | ||
| ||||
%2: | Current value[-] | |||
Index of spindle has same logical axis number as path axis | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||