ID 20385
Coordinate is out of data format. | ||||
Description | When the axis positions are calculated after deselection of synchronous operation, or after deselection of a coordinate transformation, it was found that an axis position exceeds the permissible value range. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check the machine axis positions before deselecting synchronous operation or coordinate transformation. Move to a smaller axis position in the NC program before deselecting this option. Check whether the correct kinematic type is entered in the channel parameters P-CHAN-00032 or in the NC program (#KIN ID). | |
Parameter | %1: | Error value [-] | ||
| ||||
%2: | Lower limit value [-] | |||
| ||||
%3: | Upper limit value [-] | |||
| ||||
Error type | 1, Error message from NC program. | |||
| ||||