ID 20364
No file access possible. | ||||
Description | The NC program to be opened or a log file cannot be found in the program paths configured in the start-up list. | |||
Response | Class | - | Abort NC program processing. | |
Solution | Class | - | Check whether file exists and ensure that the file is available in the configured program paths. Check NC program file names or log files for correct notation and restart. | |
Parameter | %1: | Current value | ||
Id for the invalid file access: “Main prg not found”: Main program
“Init prg not found”: Implicit subroutine at program start (P-CHAN-00119)
“Sub prg not found”: Global subroutine
“Invalid MsgSavePrgName”: #MSG SAVE..
| ||||
%2: | Block number | |||
Only with global subroutine L.. and #MSG SAVE: NC block number of program call. | ||||
%3: | Error value | |||
Only with #MSG SAVE display of the log file that cannot be opened. | ||||
Error type | 5, Error message by access on files. | |||
| ||||