ID 20245
'CONTINUE' must be programmed exclusively in NC-block. | |||
Description | In the same NC block, a control block instruction was programmed with further NC commands. After a $CONTINUE no further NC commands may be programmed. Example: Wrong:
N10 G00 X0 Y0 Z0
N20 $FOR P1=1, 10, 2
N30 $IF P1 == 8
N40 $CONTINUE G01 X100 F10000
N50 $ENDIF
:
N100 $ENDFOR
:
N1000 M30
Correct:
N10 G00 X0 Y0 Z0
N20 $FOR P1=1, 10, 2
N30 $IF P1 == 8
N35 G01 X100 F10000
N40 $CONTINUE
N50 $ENDIF
:
N100 $ENDFOR
:
N1000 M30
For further information see [PROG// Section: Counting loops] | ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and modify NC program. Move the not permissible NC commands after $CONTINUE to other NC blocks or delete them. |
Error type | 1, Error message from NC program. | ||
| |||