ID 20122
Double-programmed spindle speed definitions. | ||||
Description | More than one G function from the group of spindle speed agreements (G96/G97/G196) has been programmed in the same NC block. Example: Wrong:
N10 M03 S1000 G01 F1000 X100
N20 G96 S63 G97
:
| |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. Remove the inadmissible G function. | |
Parameter | %1: | Error value [-] | ||
Number of the inadmissible programmed G function | ||||
Error type | 1, Error message from NC program. | |||
| ||||