ID 20036
Radius of circle is 0. | |||
Description | During inactive centre point correction (G164 the centre point co-ordinates I, J, K are zero (nil) or still not programmed or the programmed co-ordinates of the circle end point are identical to the co-ordinates of the start point. From the calculation of the centre point results a circle radius with the value zero (nil) and this error message is displayed. Example: Wrong:
N10 G00 X0 Y0 Z0
N20 G164 G02 X10 F1000 (missing centre point coordinates)
N1000 M30
Wrong:
N10 G00 X0 Y0 Z0
N20 G164 G02 X0 F1000 (circle end point = start point)
N1000 M30
Correct:
N10 G00 X0 Y0 Z0
N20 G164 G02 X10 I5 F1000
| ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Correction of the invalid centre point co-ordinates I,J,K or circle end points. |
Error type | 1, Error message from NC program. | ||
| |||