ID 20025
Negative ramp time weighting programmed. | ||||
Description | The ramp time weighting with G132 was programmed with a negative value. Example: Wrong:
N10 G00 X0 Y0 Z0
N20 G132 X-10
N1000 M30
| |||
Response | Class | 1 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify NC program. Programme ramp time weighting with a positive value. | |
Parameter | %1: | Logical axis number | ||
| ||||
%2: | Error value [0.1%] | |||
| ||||
%3: | Limit value [0.1%] | |||
Lower limit value | ||||
Error type | 1, Error message from NC program.. | |||
| ||||