ID 14043
Undefined mode for handling of files (@P3). | ||||
Description | The transferred parameter @P3 defines the mode for file handling. Permitted values are 0 or 1. The value describes whether a measurement to determine parameters for Volumetric Compensation is executed (@P3=1) or a previously compensated kinematic is remeasured (@P3=0). Accordingly, the logging file is given the suffix *_log or *_control_log or the compensation file is given the suffix * or *_control. | |||
Response | Class | - | Error: Transition to error state. Complete reset of the NC channel necessary. | |
Solution | Class | - | Check parameter setting and correct the input parameter @P3. | |
Parameter | %1: | Current value | ||
| ||||
%2: | Lower limit value | |||
| ||||
%3: | Upper limit value | |||
| ||||
Error type | 1, Error message from the NC program | |||
| ||||