ID 13223
Travel distance (@P3) is too short. | |||
Description | The maximum travel distance for a measuring stroke at constant velocity must be greater than twice the parameterised backlash @P7. Select a sufficiently large measuring distance to reach the measurement velocity. It is recommended to parameterise a measuring distance that is much greater than the backlash. The multiple IDs show which parameter is defined incorrectly: 1. ABS[@P3] = 0 The distance is parameterised as 0, 2. ABS[@P3]-2*@P7 <= 0 the travel distance less twice the parameterised backlash is less than or equal to 0 | ||
Response | Class | - | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | - | Check the two parameters @P3 and @P7 and enter a sufficiently large value. |
Error type | 1, Error message from the NC program | ||
| |||