ID 1705

Buffer allocation for job acknowledge of single axis failed.

Description

There is no buffer available for the acknowledgement of the job of a single axis. Possible cause is that previously many jobs were commanded but not yet processed.

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Reduce number of jobs for the single axes.

Parameter

%1:

Logical axis number [-]

Logical axis number of single axis P-AXIS-00016

%2:

Current value [-]

Job ID

%3:

Current value [-]

Program line number

%4:

Current value [-]

Identifier for machining plane where the error was reported for this job.

%5:

Current value [-]

Optional: Identifier of function block that commanded the job in the PLC. If the value is 0, the job was not output via a PLCopen function block, it was written directly to the HLI.

Error type

1, Error message from NC program.