ID 22264
The selection of a kinematic transformation is not permitted when conveyor synchronisation is active. | |||
Description | While the conveyor tracking function is active, a transformation may neither be selected nor deselected between selection with #SYNC IN and deselection with #SYNC OUT. Program example with error with deselection of transformation: N010 #KIN ID[37] N020 G0 G90 X34.9485 Y-18.0290 Z34.0535 N020 #TRAFO ON ;… N070 #SYNC IN [CONVEYOR … ;… N110 #TRAFO OFF (Error ID 22264) N100 #SYNC OUT [FEED_CONT=5] ;…
Corrected example: N010 #KIN ID[37] N020 G0 G90 X34.9485 Y-18.0290 Z34.0535 N020 #TRAFO ON ;… N070 #SYNC IN [CONVEYOR … ;… N100 #SYNC OUT [FEED_CONT=5] N110 #TRAFO OFF ;… | ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and modify the NC program; relocate the selection or deselection of the transformation in the program. |
Error type | 1, Error message from NC program. | ||
| |||