ID 315003
The cut-off frequency of the low-pass filter for distance control is out of permissible range. | ||||
Description | The cut-off frequency can be defined for the low-pass filter for distance control (see FCT-M3). For axis-specific distance control using P-AXIS-00508, and for 3d distance control using P-CHAN-00817. The parameter may not be smaller than the specified limit value. | |||
Response | Class | 1 | Output a warning and correct the parameter to the minimum value. | |
Solution | Class | 1 | Check and correct the parameter accordingly.
| |
Parameter | %1: | Logical axis number [-] or Logical channel number [-] | ||
Logical axis number P-AXIS-00016 of the axis affected for axis-specific distance control, | ||||
%2: | Error value [Hz] | |||
Parameterised cut-off frequency | ||||
%3: | Lower limit value [Hz] | |||
Minimum cut-off frequency | ||||
%4: | Corrected value [Hz] | |||
Corrected cut-off frequency | ||||
Error type | - | |||
| ||||