ID 315002
Number of filter cycles for distance control exceeds valid range. | ||||
Description | Distance control (see FCT-M3) uses an average value filter to smooth the sensor signal. However, the number of specified filter cycles for this filter exceeds the maximum permissible value. For axis-specific distance control using P-AXIS-00413, and for 3d distance control using P-CHAN-00800. | |||
Response | Class | 1 | Output a warning and correct the parameter to the minimum value. | |
Solution | Class | 1 | Check and correct the parameter accordingly.
| |
Parameter | %1: | Logical axis number [-] or Logical channel number [-] | ||
Logical axis number P-AXIS-00016 of the axis affected for axis-specific distance control, | ||||
%2: | Error value [-] | |||
Parameterised value for the number of filter cycles | ||||
%3: | Corrected value [-] | |||
Correct the value for the number of filter cycles | ||||
%4: | Upper limit value [-] | |||
Maximum value for the number.of filter cycles | ||||
Error type | - | |||
| ||||