ID 315008

Smoothing factor for distance control is out of permissible range.

Description

The smoothing factor for the exponential averaging filter for distance control [FCT-M3] may not exceed the specified limits.

Parameterisation is executed using:

  • P-AXIS-00784 for axis-specific distance control
  • P-CHAN-00827 for 3D distance control

Response

Class

1

Output the warning and limit smoothing factor.

Solution

Class

1

Check and correct the parameter for the smoothing factor.

Parameter

%1:

Logical axis number [-] or Logical channel number [-]

Logical axis number P-AXIS-00016 of the axis affected for axis-specific distance control,
logical channel number P-CHAN-00400 for 3D distance control.

%2:

Error value [-]

Incorrectly parameterised value of smoothing factor

%3:

Lower limit value [-]

Minimum value of smoothing factor

%4:

Upper limit value [-]

Maximum value of smoothing factor

%5:

Corrected value [-]

Corrected value of smoothing factor

Error type

-