ID 70569
Changing gantry link only possible at standstill. | ||||
Description | A change in gantry coupling is only possible when all the axes involved are at standstill. | |||
Response | Class | 7 | Controlled halt of the axis, the control loop is closed. | |
Solution | Class | 5 | Stop the axes involved before sending the command to change the gantry coupling. | |
Parameter | %1: | Current value [-] | ||
Logical axis number P-AXIS-00016 of the slave axis belonging to a gantry combination | ||||
%2: | Current value [-] | |||
Channel ID | ||||
%3: | Current value [-] | |||
Value for gantry change request. | ||||
%4: | Upper limit value [-] | |||
Logical axis number P-AXIS-00016 of master axis belonging to a gantry combination | ||||
Error type | 11, Error message from position controller. | |||
| ||||