ID 22242
Programmed and active kinematic IDs are not identical. | ||||
Description | With simple standard kinematics, the kinematic ID can be optionally specified when singularity monitoring is selected or deselected with #SINGULARITY AVOIDANCE ON/OFF. In this case, the kinematic ID must be identical with the ID of the currently active transformation. The kinematic ID need only be specified for #SINGULARITY AVOIDANCE ON/OFF with transformations that consist of couple kinematics. Here, the programmed ID addresses the ID of a subordinate member kinematic of the active transformation. | |||
Response | Class | 2 | Abort NC program processing. | |
Solution | Class | 3 | Check and modify the NC program. There are 2 options for this:
| |
Parameter | %1: | Current value [-] | ||
Programmed kinematic ID | ||||
%2: | Current value [-] | |||
Kinematic ID of the currently active transformation | ||||
Error type | 1, Error message from NC program. | |||
| ||||