ID 51072
Motion blocks are not allowed after #ESCAPE PATH POST SEQUENCE. | ||||
Description | Programming a motion block is not permitted after processing #ESCAPE PATH POST SEQUENCE. #ESCAPE PATH Command structure:
Incorrect example (N75) N010 #ESCAPE PATH DEF BEGIN
N020 #CS ON [APP] [@PL4,@PL5,@PL6,@PL7,@PL8,@PL9]
N030 #ESCAPE PATH BACKWARD STOP
N040 G01 Z7.07 F30
N050 G01 Y0
N060 G01 Z0
N070 #ESCAPE PATH POST SEQUENCE
N075 G01 Y0.1 (Incorrectly placed motion block)
N080 #CS DEL ALL
N090 #ESCAPE PATH DEF END
N100 M30 | |||
Response | Class | 2 | NC program execution aborted and transition to error state | |
Solution | Class | 3 | Check and modify the NC program | |
Parameter | %1: | Current value [-] | ||
Block number of #ESCAPE PATH POST SEQUENCE | ||||
Error type | 1, Error message from NC program. | |||
|