ID 120815

Deviation between the defined and actual pre-output position of the M/H function exceeds the permissible tolerance.

Description

Due to a limitation in the microjoint function, an M/H function with a pre-output cannot be output at the required position.

The path and the number of blocks can be limitations.

The number of blocks can be affected by P-CHAN-00603. With contour-changing functions, e.g. contouring, the number of blocks is increased compared to the programmed blocks.

The specified tolerance value (P-CHAN-00760) was exceeded for such a deviation from the required position.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Increase tolerance (P-CHAN-00760) if possible. Otherwise, check what limitation obstructs the planned pre-output of the M/H function,.or increase P-CHAN-00603.

Parameter

%1:

Expected value [0.1 µm]

Specified tolerance value for permitted deviation.

%2:

Current value [0.1 µm]

Current actual deviation.

%3:

Block number [-]

Block number at which an attempt was made to output the M/H function.

%4:

Current value [-]

Current number of blocks available for pre-output; this may differ from the size defined in P-CHAN-00603, for example due to a #FLUSH.

%5:

Upper limit value [-]

Value of P-CHAN-00603

Error type

1, Error message from NC program.