Synchronisation types MET_SVS, MEP_SVS
Synchronisation types with synchronisation before block with time or path-related pre-output. The associated pre-output values are set in P-CHAN-00070 (m_pre_outp[i]):

![]() | If several M functions of this synchronisation type are programmed overlapped in relation to their effective ranges and positions in the NC program, the first programmed M function in the NC block sequence defines the earliest time of output for all following M functions (see examples below). This may cause an offset or change in order of the output times. Therefore, avoid range overlaps as far as possible. |
Notice | |
Please note with MET_SVS codes that the pre-output time is planned due to the required synchronisation with path motions based on a feed profile with end velocity 0. As a result, there may be deviations between the planned and the actual motion times up to the M code (block limit). This is shown in the figure below. |

Programming Example
Range overlap and output with MEP_SVS, MET_SVS