Scaling factor (P-AXIS-00728)
P-AXIS-00728 | Scaling factor | |
Description | This parameter executes a scaling for reading and writing the drive object. This parameter only acts if the scaling type P-AXIS-00724 is set to 'LINEAR'. | |
Parameter | antr.fixed_stop.drive_ident[i].scaling_factor | |
Data type | REAL64 | |
Data range | Unequal to 0 | |
Axis types | T, R | |
Dimension | T: - | R: - |
Default value | 1.0 | |
drive types. | SERCOS, CANopen | |
Remarks | Example: The torque limit in the SERCOS drive is specified in per mil of the maximum motor torque. However, the torque should be specified in percent in the NC program: antr.fixed_stop.drive_ident[0].id TORQUE_LIMIT antr.fixed_stop.drive_ident[0].wr_ident S_0_0092 antr.fixed_stop.drive_ident[0].scaling_type LINEAR antr.fixed_stop.drive_ident[0].scaling_factor 10 | |