Band-pass filters

Frequency response

Bandwidth ΔΩ=f0 - fu within the pass-band of the band-pass filter is defined by the cut-off frequencies f0 and fu. They are defined as frequencies where the amplitude has exceeded –3dB (~0.707). When a band-pass filter is configured, the bandwidth is defined by specifying the quality factor (filter[i].guete). The quality factor is the ratio of the characteristic filter frequency to bandwidth ΔΩ:

Band-pass filters 1:

For this reason, the frequency range f0-fu reduces as the quality rises. The following relationship exists between the characteristic frequency of the band-pass filter and the cut-off frequencies f0 and fu (geometric mean):

Band-pass filters 2:

With band-pass filters, the filter prototype has only a minor influence on filter response.

Band-pass filters 3:
Amplitude frequency response of band-pass filters (4th order, quality = 1)