Activating and reading automatic external signals from the robot controller
Description
The function block KRC_AutomaticExternal activates the Automatic External interface and reads the interface signals.
The function block KRC_AutoStart can be used to simplify use of KRC_AutomaticExternal.
(>>> Setting KRC_AutomaticExternal inputs automatically)
![]() | The function block requires the Automatic External mode of the robot system. Further information about this function is provided in the operating and programming instructions for the system software. |
![]() | The function block may only be instanced once per axis group. In the case of multiple instancing, the signals of the most recently called function block are output. |
Inputs
Parameter | Type | Signal name (robot controller) | Description |
|---|---|---|---|
AxisGroupIdx | INT | — | Index of axis group
|
MOVE_ENABLE | BOOL | $MOVE_ENABLE | TRUE = motion enable for the robot Notice: This system variable is monitored by the robot controller in all operating modes. |
CONF_MESS | BOOL | $CONF_MESS | TRUE = acknowledgement of error messages |
DRIVES_ON | BOOL | $DRIVES_ON | TRUE = activation of the robot drives |
DRIVES_OFF | BOOL | $DRIVES_OFF | FALSE = deactivation of the robot drives |
EXT_START | BOOL | $EXT_START | TRUE = start or continuation of robot program execution |
RESET | BOOL | — | Selects the mxAutomation robot program in the case of a rising edge of the signal and starts it. First, all buffered statements are aborted. |
ENABLE_T1 | BOOL | — | TRUE = enabling of T1 mode The signal $MOVE_ENABLE is suppressed in the absence of enabling. The robot cannot be moved. |
ENABLE_T2 | BOOL | — | TRUE = enabling of T2 mode The signal $MOVE_ENABLE is suppressed in the absence of enabling. The robot cannot be moved. |
ENABLE_AUT | BOOL | — | TRUE = enabling of Automatic mode The signal $MOVE_ENABLE is suppressed in the absence of enabling. The robot cannot be moved. |
ENABLE_EXT | BOOL | — | TRUE = enabling of Automatic External mode The signal $MOVE_ENABLE is suppressed in the absence of enabling. The robot cannot be moved. |
Outputs
Parameter | Type | Signal name (robot controller) | Description |
|---|---|---|---|
Valid | BOOL | — | TRUE = data are valid |
RC_RDY1 | BOOL | $RC_RDY1 | TRUE = robot controller ready for program start |
ALARM_STOP | BOOL | $ALARM_STOP | FALSE = robot stop by EMERGENCY STOP |
USER_SAFE | BOOL | $USER_SAF | FALSE = operator safety violated |
PERI_RDY | BOOL | $PERI_RDY | TRUE = robot drives activated |
ROB_CAL | BOOL | $ROB_CAL | TRUE = robot axes mastered |
IO_ACTCONF | BOOL | $IO_ACTCONF | TRUE = Automatic External interface active |
STOPMESS | BOOL | $STOPMESS | TRUE = safety circuit interrupted (robot fault) |
INT_E_STOP | BOOL | Int. E-Stop | TRUE = external EMERGENCY STOP FALSE = EMERGENCY STOP device pressed on the smartPAD |
PRO_ACT | BOOL | $PRO_ACT | TRUE = process active at robot level |
APPL_RUN | BOOL | APPL_RUN | TRUE = robot program running |
PRO_MOVE | BOOL | $PRO_MOVE | TRUE = synchronous robot motion active |
ON_PATH | BOOL | $ON_PATH | TRUE = robot on programmed path |
NEAR_POSRET | BOOL | $NEAR_POSRET | TRUE = robot near most recently saved position on the programmed path (after leaving path) |
ROB_STOPPED | BOOL | $ROB_STOPPED | TRUE = robot is at standstill |
T1 | BOOL | $T1 | TRUE = mode T1 selected |
T2 | BOOL | $T2 | TRUE = mode T2 selected |
AUT | BOOL | $AUT | TRUE = operating mode Automatic selected |
EXT | BOOL | $EXT | TRUE = operating mode Automatic External selected |