Reading outputs of the robot system
Description
The function block KRC_ReadAxisGroup is used to assign the parameter KRC4_Input to the parameter AxisGroupIdx. The following function blocks always refer to the same robot system using the parameter AxisGroupIdx.
![]() | The function block KRC_ReadAxisGroup must always be called at the start of the program. Access to the parameter AxisGroupIdx is only permissible between the function blocks KRC_ReadAxisGroup and KRC_WriteAxisGroup. |
![]() | The function block may only be instanced once per axis group. In the case of multiple instancing, the signals of the most recently called function block are output. |
Inputs
Parameter | Type | Description |
|---|---|---|
KRC4_Input | POINTER TO BYTE | Defines the start index of the output range of the robot controller |
AxisGroupIdx | INT | Index of axis group
|
Outputs
Parameter | Type | Description |
|---|---|---|
ErrorID | DINT | Error number |
Error | BOOL | TRUE = error in function block |