Teaching points

Description

The function block KRC_TouchUP can be used to teach a point directly in the PLC. Tool, base and interpolation mode of this point are automatically saved by the function block.

Teaching points 1:

Inputs

Parameter

Type

Description

PositionArray

POSITION_
ARRAY

Array with the taught points and the corresponding coordinate systems

Note: The array can be used directly in the PLC.

(>>> POSITION_ARRAY)

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

TRUE = the point is taught

Index

INT

Number under which the taught point is saved in the PLC

  • 1 … 100

Outputs

Parameter

Type

Description

Done

BOOL

TRUE = statement has been executed

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number