Reading the maximum of measured collision detection values

Description

The function block KRC_CDReadMaxMeasured is used to read the maximum of measured collision detection values since the last reset.

Reading the maximum of measured collision detection values 1:

Inputs

Parameter

Type

Description

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

The statement is executed in the case of a rising edge of the signal.

Outputs

Parameter

Type

Description

Busy

BOOL

TRUE = statement is currently being transferred or has already been transferred

Done

BOOL

TRUE = statement has been executed

Aborted

BOOL

TRUE = statement has been aborted

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number

MaxMeasuredA1

INT

Maximum of measured collision detection values since the last reset for robot axis A1 … A6

  • 0 … 500

MaxMeasuredA2

INT

MaxMeasuredA3

INT

MaxMeasuredA4

INT

MaxMeasuredA5

INT

MaxMeasuredA6

INT

MaxMeasuredE1

INT

Maximum of measured collision detection values since the last reset for external axis E1 … E6

  • 0 … 500

MaxMeasuredE2

INT

MaxMeasuredE3

INT

MaxMeasuredE4

INT

MaxMeasuredE5

INT

MaxMeasuredE6

INT