Data of a Cartesian workspace
The data of a Cartesian workspace which are used in certain function blocks are described below.
Origin and orientation
The origin and orientation of a Cartesian workspace are specified with the following elements. These elements refer to the WORLD coordinate system and are defined in the variable BOX.
|
Element |
Data type |
Unit |
Minimum |
Maximum |
|---|---|---|---|---|
|
X |
REAL |
mm |
- |
- |
|
Y |
REAL |
mm |
- |
- |
|
Z |
REAL |
mm |
- |
- |
|
A |
REAL |
° |
-180 |
180 |
|
B |
REAL |
° |
-180 |
180 |
|
C |
REAL |
° |
-180 |
180 |
Dimensions
The dimensions of a Cartesian workspace are specified with the following elements.
|
Element |
Data type |
Unit |
|---|---|---|
|
X1 |
REAL |
mm |
|
X2 |
REAL |
mm |
|
Y1 |
REAL |
mm |
|
Y2 |
REAL |
mm |
|
Z1 |
REAL |
mm |
|
Z2 |
REAL |
mm |