Reading the status of the workspaces
Description
The function block KRC_ReadWorkstates reads the current status of the workspaces. The status of the workspaces is updated cyclically.
Inputs
Parameter |
Type |
Description |
---|---|---|
AxisGroupIdx |
INT |
Index of axis group
|
Outputs
Parameter |
Type |
Description |
---|---|---|
Valid |
BOOL |
TRUE = data are valid |
WORKSTATE1 |
BOOL |
Status of the workspaces |
WORKSTATE2 |
BOOL | |
WORKSTATE3 |
BOOL | |
WORKSTATE4 |
BOOL | |
WORKSTATE5 |
BOOL | |
WORKSTATE6 |
BOOL | |
WORKSTATE7 |
BOOL | |
WORKSTATE8 |
BOOL | |
AXWORKSTATE1 |
BOOL | |
AXWORKSTATE2 |
BOOL | |
AXWORKSTATE3 |
BOOL | |
AXWORKSTATE4 |
BOOL | |
AXWORKSTATE5 |
BOOL | |
AXWORKSTATE6 |
BOOL | |
AXWORKSTATE7 |
BOOL | |
AXWORKSTATE8 |
BOOL | |
Error |
BOOL |
TRUE = error in function block |
ErrorID |
DINT |
Error number |